Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
1.
Am J Physiol Cell Physiol ; 326(4): C1262-C1271, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38497111

RESUMO

Defining the oxygen level that induces cell death within 3-D tissues is vital for understanding tissue hypoxia; however, obtaining accurate measurements has been technically challenging. In this study, we introduce a noninvasive, high-throughput methodology to quantify critical survival partial oxygen pressure (pO2) with high spatial resolution within spheroids by using a combination of controlled hypoxic conditions, semiautomated live/dead cell imaging, and computational oxygen modeling. The oxygen-permeable, micropyramid patterned culture plates created a precisely controlled oxygen condition around the individual spheroid. Live/dead cell imaging provided the geometric information of the live/dead boundary within spheroids. Finally, computational oxygen modeling calculated the pO2 at the live/dead boundary within spheroids. As proof of concept, we determined the critical survival pO2 in two types of spheroids: isolated primary pancreatic islets and tumor-derived pseudoislets (2.43 ± 0.08 vs. 0.84 ± 0.04 mmHg), indicating higher hypoxia tolerance in pseudoislets due to their tumorigenic origin. We also applied this method for evaluating graft survival in cell transplantations for diabetes therapy, where hypoxia is a critical barrier to successful transplantation outcomes; thus, designing oxygenation strategies is required. Based on the elucidated critical survival pO2, 100% viability could be maintained in a typically sized primary islet under the tissue pO2 above 14.5 mmHg. This work presents a valuable tool that is potentially instrumental for fundamental hypoxia research. It offers insights into physiological responses to hypoxia among different cell types and may refine translational research in cell therapies.NEW & NOTEWORTHY Our study introduces an innovative combinatory approach for noninvasively determining the critical survival oxygen level of cells within small cell spheroids, which replicates a 3-D tissue environment, by seamlessly integrating three pivotal techniques: cell death induction under controlled oxygen conditions, semiautomated imaging that precisely identifies live/dead cells, and computational modeling of oxygen distribution. Notably, our method ensures high-throughput analysis applicable to various cell types, offering a versatile solution for researchers in diverse fields.


Assuntos
Ilhotas Pancreáticas , Oxigênio , Humanos , Oxigênio/metabolismo , Hipóxia/metabolismo , Ilhotas Pancreáticas/metabolismo , Esferoides Celulares/metabolismo , Hipóxia Celular , Sobrevivência Celular
2.
Bioeng Transl Med ; 9(1): e10616, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38193119

RESUMO

The characterization of atherosclerotic plaques to predict their vulnerability to rupture remains a diagnostic challenge. Despite existing imaging modalities, none have proven their abilities to identify metabolically active oxidized low-density lipoprotein (oxLDL), a marker of plaque vulnerability. To this end, we developed a machine learning-directed electrochemical impedance spectroscopy (EIS) platform to analyze oxLDL-rich plaques, with immunohistology serving as the ground truth. We fabricated the EIS sensor by affixing a six-point microelectrode configuration onto a silicone balloon catheter and electroplating the surface with platinum black (PtB) to improve the charge transfer efficiency at the electrochemical interface. To demonstrate clinical translation, we deployed the EIS sensor to the coronary arteries of an explanted human heart from a patient undergoing heart transplant and interrogated the atherosclerotic lesions to reconstruct the 3D EIS profiles of oxLDL-rich atherosclerotic plaques in both right coronary and left descending coronary arteries. To establish effective generalization of our methods, we repeated the reconstruction and training process on the common carotid arteries of an unembalmed human cadaver specimen. Our findings indicated that our DenseNet model achieves the most reliable predictions for metabolically vulnerable plaque, yielding an accuracy of 92.59% after 100 epochs of training.

3.
Artigo em Inglês | MEDLINE | ID: mdl-36752517

RESUMO

A wide variety of transition metals, including copper and gold, have been successfully used as substrates for graphene growth. On the other hand, it has been challenging to grow graphene on silver, so realistic applications by combining graphene and silver for improved electrode stability and enhanced surface plasmon resonance in organic light-emitting diodes and biosensing have not been realized to date. Here, we demonstrate the surface passivation of silver through the single-step rapid growth of nanocrystalline multilayer graphene on silver via low-temperature plasma-enhanced chemical vapor deposition (PECVD). The effect of the growth time on the graphene quality and the underlying silver characteristics is investigated by Raman spectroscopy, X-ray diffraction, atomic force microscopy, X-ray photoelectron spectroscopy (XPS), and cross-sectional annular dark-field scanning transmission electron microscopy (ADF-STEM). These results reveal nanocrystalline graphene structures with turbostratic layer stacking. Based on the XPS and ADF-STEM results, a PECVD growth mechanism of graphene on silver is proposed. The multilayer graphene also provides excellent long-term protection of the underlying silver surface from oxidation after 5 months of air exposure. This development thus paves the way toward realizing technological applications based on graphene-protected silver surfaces and electrodes as well as hybrid graphene-silver plasmonics.

4.
Biofabrication ; 15(1)2022 12 20.
Artigo em Inglês | MEDLINE | ID: mdl-36537072

RESUMO

The need for maintaining cell-spheroid viability and function within high-density cultures is unmet for various clinical and experimental applications, including cell therapies. One immediate application is for transplantation of pancreatic islets, a clinically recognized treatment option to cure type 1 diabetes; islets are isolated from a donor for subsequent culture prior to transplantation. However, high seeding conditions cause unsolicited fusion of multiple spheroids, thereby limiting oxygen diffusion to induce hypoxic cell death. Here we introduce a culture dish incorporating a micropyramid-patterned surface to prevent the unsolicited fusion and oxygen-permeable bottom for optimal oxygen environment. A 400µm-thick, oxygen-permeable polydimethylsiloxane sheet topped with micropyramid pattern of 400µm-base and 200µm-height was fabricated to apply to the 24-well plate format. The micropyramid pattern separated the individual pancreatic islets to prevent the fusion of multiple islets. This platform supported the high oxygen demand of islets at high seeding density at 260 islet equivalents cm-2, a 2-3-fold higher seeding density compared to the conventional islet culture used in a preparation for the clinical islet transplantations, demonstrating improved islet morphology, metabolism and function in a 4 d-culture. Transplantation of these islets into immunodeficient diabetic mice exhibited significantly improved engraftment to achieve euglycemia compared to islets cultured in the conventional culture wells. Collectively, this simple design modification allows for high-density cultures of three-dimensional cell spheroids to improve the viability and function for an array of investigational and clinical replacement tissues.


Assuntos
Diabetes Mellitus Experimental , Transplante das Ilhotas Pancreáticas , Ilhotas Pancreáticas , Camundongos , Animais , Oxigênio/metabolismo , Diabetes Mellitus Experimental/metabolismo , Transplante das Ilhotas Pancreáticas/métodos , Hipóxia/metabolismo
5.
BMC Biomed Eng ; 4(1): 1, 2022 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-35073998

RESUMO

BACKGROUND: Detection of locally increased blood concentration and perfusion is critical for assessment of functional cortical activity as well as diagnosis of conditions such as intracerebral hemorrhage (ICH). Current paradigms for assessment of regional blood concentration in the brain rely on computed tomography (CT), magnetic resonance imaging (MRI), and perfusion blood oxygen level dependent functional magnetic resonance imaging (BOLD-fMRI). RESULTS: In this study, we developed computational models to test the feasibility of novel magnetic sensors capable of detecting hemodynamic changes within the brain on a microtesla-level. We show that low-field magnetic sensors can accurately detect changes in magnetic flux density and eddy current damping signals resulting from increases in local blood concentration. These models predicted that blood volume changes as small as 1.26 mL may be resolved by the sensors, implying potential use for diagnosis of ICH and assessment of regional blood flow as a proxy for cerebral metabolism and neuronal activity. We then translated findings from our computational model to demonstrate feasibility of accurate detection of modeled ICH in a simulated human cadaver setting. CONCLUSIONS: Overall, microtesla-level magnetic scanning is feasible, safe, and has distinct advantages compared to current standards of care. Computational modeling may facilitate rapid prototype development and testing of novel medical devices with minimal risk to human participants prior to device construction and clinical trials.

6.
IEEE Trans Biomed Eng ; 69(2): 734-745, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34383642

RESUMO

OBJECTIVE: Atherosclerosis is a chronic immuno-inflammatory condition emerging in arteries and considered the cause of a myriad of cardiovascular diseases. Atherosclerotic lesion characterization through invasive imaging modalities is essential in disease evaluation and determining intervention strategy. Recently, electrical properties of the lesions have been utilized in assessing its vulnerability mainly owing to its capability to differentiate lipid content existing in the lesion, albeit with limited detection resolution. Electrical impedance tomography is the natural extension of conventional spectrometric measurement by incorporating larger number of interrogating electrodes and advanced algorithm to achieve imaging of target objects and thus provides significantly richer information. It is within this context that we develop Outward Electrical Impedance Tomography (OEIT), aimed at intravascular imaging for atherosclerotic lesion characterization. METHODS: We utilized flexible electronics to establish the 32-electrode OEIT device with outward facing configuration suitable for imaging of vessels. We conducted comprehensive studies through simulation model and ex vivo setup to demonstrate the functionality of OEIT. RESULTS: Quantitative characterization for OEIT regarding its proximity sensing and conductivity differentiation was achieved using well-controlled experimental conditions. Imaging capability for OEIT was further verified with phantom setup using porcine aorta to emulate in vivo environment. CONCLUSION: We have successfully demonstrated a novel tool for intravascular imaging, OEIT, with unique advantages for atherosclerosis detection. SIGNIFICANCE: This study demonstrates for the first time a novel electrical tomography-based platform for intravascular imaging, and we believe it paves the way for further adaptation of OEIT for intravascular detection in more translational settings and offers great potential as an alternative imaging tool for medical diagnosis.


Assuntos
Aterosclerose , Tomografia , Animais , Impedância Elétrica , Imagens de Fantasmas , Suínos , Tomografia/métodos , Tomografia Computadorizada por Raios X
7.
Sci Rep ; 11(1): 20144, 2021 10 11.
Artigo em Inglês | MEDLINE | ID: mdl-34635738

RESUMO

Pulmonary function testing (PFT) allows for quantitative analysis of lung function. However, as a result of the coronavirus disease 2019 (COVID-19) pandemic, a majority of international medical societies have postponed PFTs in an effort to mitigate disease transmission, complicating the continuity of care in high-risk patients diagnosed with COVID-19 or preexisting lung pathologies. Here, we describe the development of a non-contact wearable pulmonary sensor for pulmonary waveform analysis, pulmonary volume quantification, and crude thoracic imaging using the eddy current (EC) phenomenon. Statistical regression analysis is performed to confirm the predictive validity of the sensor, and all data are continuously and digitally stored with a sampling rate of 6,660 samples/second. Wearable pulmonary function sensors may facilitate rapid point-of-care monitoring for high-risk individuals, especially during the COVID-19 pandemic, and easily interface with patient hospital records or telehealth services.


Assuntos
COVID-19/diagnóstico , Monitorização Fisiológica/instrumentação , Sistemas Automatizados de Assistência Junto ao Leito , Testes de Função Respiratória/instrumentação , Dispositivos Eletrônicos Vestíveis , COVID-19/epidemiologia , COVID-19/transmissão , COVID-19/virologia , Estudos de Viabilidade , Voluntários Saudáveis , Humanos , Controle de Infecções , Transmissão de Doença Infecciosa do Paciente para o Profissional/prevenção & controle , Monitorização Fisiológica/métodos , Pandemias/prevenção & controle , Testes de Função Respiratória/métodos , Fenômenos Fisiológicos Respiratórios
8.
Sci Rep ; 11(1): 19859, 2021 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-34615918

RESUMO

Non-alcoholic fatty liver disease (NAFLD) is one of the most common causes of cardiometabolic diseases in overweight individuals. While liver biopsy is the current gold standard to diagnose NAFLD and magnetic resonance imaging (MRI) is a non-invasive alternative still under clinical trials, the former is invasive and the latter costly. We demonstrate electrical impedance tomography (EIT) as a portable method for detecting fatty infiltrate. We enrolled 19 overweight subjects to undergo liver MRI scans, followed by EIT measurements. The MRI images provided the a priori knowledge of the liver boundary conditions for EIT reconstruction, and the multi-echo MRI data quantified liver proton-density fat fraction (PDFF%) to validate fat infiltrate. Using the EIT electrode belts, we circumferentially injected pairwise current to the upper abdomen, followed by acquiring the resulting surface-voltage to reconstruct the liver conductivity. Pearson's correlation analyses compared EIT conductivity or MRI PDFF with body mass index, age, waist circumference, height, and weight variables. We reveal that the correlation between liver EIT conductivity or MRI PDFF with demographics is statistically insignificant, whereas liver EIT conductivity is inversely correlated with MRI PDFF (R = -0.69, p = 0.003, n = 16). As a pilot study, EIT conductivity provides a portable method for operator-independent and cost-effective detection of hepatic steatosis.


Assuntos
Impedância Elétrica , Fígado Gorduroso/diagnóstico por imagem , Fígado Gorduroso/patologia , Sobrepeso/patologia , Tomografia/métodos , Adulto , Idoso , Algoritmos , Biomarcadores , Biópsia , Pesos e Medidas Corporais , Gerenciamento Clínico , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade
9.
Transl Vis Sci Technol ; 10(10): 14, 2021 08 12.
Artigo em Inglês | MEDLINE | ID: mdl-34705041

RESUMO

Purpose: To report on the safety and efficacy of the 256-channel Intelligent Micro Implant Eye epiretinal prosthesis system (IMIE 256). Methods: The IMIE 256 implants were implanted in the right eyes of five subjects with end-stage retinitis pigmentosa. Following implantation, the subjects underwent visual rehabilitation training for 90 days, and their visual performance was evaluated using the grating visual acuity test, Tumbling E visual acuity test, direction of motion, square localization, and orientation and mobility test. To evaluate the safety of the IMIE 256, all adverse events were recorded. Results: Subjects performed significantly better on all evaluations with the IMIE 256 system on as compared with the performance at baseline or with the system off. There was a steady improvement in performance at each observation interval, indicating that the training and/or practice helped the subjects use the IMIE 256. There were two serious adverse events-electrode array movement and low intraocular pressure in one subject, which resolved with surgery. There were no other adverse events observed except those expected in the course of postoperative healing. Conclusions: These results show an improved safety and efficacy profile compared with that of the Argus II implant. Further clinical trials are needed to confirm these results in a larger number of subjects and over longer durations. Translational Relevance: To our knowledge, this study reports the first in-human data from a high-density (256 electrodes) epiretinal implant to restore sight to a subset of blind patients.


Assuntos
Retinite Pigmentosa , Próteses Visuais , Eletrodos Implantados , Humanos , Retina , Acuidade Visual
10.
Neurosurg Focus ; 51(1): E15, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34198251

RESUMO

OBJECTIVE: Spontaneous intracerebral hemorrhage occurs in an estimated 10% of stroke patients, with high rates of associated mortality. Portable diagnostic technologies that can quickly and noninvasively detect hemorrhagic stroke may prevent unnecessary delay in patient care and help rapidly triage patients with ischemic versus hemorrhagic stroke. As such, the authors aimed to develop a rapid and portable eddy current damping (ECD) hemorrhagic stroke sensor for proposed in-field diagnosis of hemorrhagic stroke. METHODS: A tricoil ECD sensor with microtesla-level magnetic field strengths was constructed. Sixteen gelatin brain models with identical electrical properties to live brain tissue were developed and placed within phantom skull replicas, and saline was diluted to the conductivity of blood and placed within the brain to simulate a hemorrhage. The ECD sensor was used to detect modeled hemorrhages on benchtop models. Data were saved and plotted as a filtered heatmap to represent the lesion location. The individuals performing the scanning were blinded to the bleed location, and sensors were tangentially rotated around the skull models to localize blood. Data were also used to create heatmap images using MATLAB software. RESULTS: The sensor was portable (11.4-cm maximum diameter), compact, and cost roughly $100 to manufacture. Scanning time was 2.43 minutes, and heatmap images of the lesion were produced in near real time. The ECD sensor accurately predicted the location of a modeled hemorrhage in all (n = 16) benchtop experiments with excellent spatial resolution. CONCLUSIONS: Benchtop experiments demonstrated the proof of concept of the ECD sensor for rapid transcranial hemorrhagic stroke diagnosis. Future studies with live human participants are warranted to fully establish the feasibility findings derived from this study.


Assuntos
Isquemia Encefálica , Acidente Vascular Cerebral Hemorrágico , Acidente Vascular Cerebral , Hemorragia Cerebral/diagnóstico por imagem , Estudos de Viabilidade , Humanos , Acidente Vascular Cerebral/diagnóstico por imagem
11.
Neurosurg Focus ; 51(1): E11, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34198255

RESUMO

OBJECTIVE: Stroke is a leading cause of morbidity and mortality. Current diagnostic modalities include CT and MRI. Over the last decade, novel technologies to facilitate stroke diagnosis, with the hope of shortening time to treatment and reducing rates of morbidity and mortality, have been developed. The authors conducted a systematic review to identify studies reporting on next-generation point-of-care stroke diagnostic technologies described within the last decade. METHODS: A systematic review was performed according to PRISMA guidelines to identify studies reporting noninvasive stroke diagnostics. The QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies-2) tool was utilized to assess risk of bias. PubMed, Web of Science, and Scopus databases were utilized. Primary outcomes assessed included accuracy and timing compared with standard imaging, potential risks or complications, potential limitations, cost of the technology, size/portability, and range/size of detection. RESULTS: Of the 2646 reviewed articles, 19 studies met the inclusion criteria and included the following modalities of noninvasive stoke detection: microwave technology (6 studies, 31.6%), electroencephalography (EEG; 4 studies, 21.1%), ultrasonography (3 studies, 15.8%), near-infrared spectroscopy (NIRS; 2 studies, 10.5%), portable MRI devices (2 studies, 10.5%), volumetric impedance phase-shift spectroscopy (VIPS; 1 study, 5.3%), and eddy current damping (1 study, 5.3%). Notable medical devices that accurately predicted stroke in this review were EEG-based diagnosis, with a maximum sensitivity of 91.7% for predicting a stroke, microwave-based diagnosis, with an area under the receiver operating characteristic curve (AUC) of 0.88 for differentiating ischemic stroke and intracerebral hemorrhage (ICH), ultrasound with an AUC of 0.92, VIPS with an AUC of 0.93, and portable MRI with a diagnostic accuracy similar to that of traditional MRI. NIRS offers significant potential for more superficially located hemorrhage but is limited in detecting deep-seated ICH (2.5-cm scanning depth). CONCLUSIONS: As technology and computational resources have advanced, several novel point-of-care medical devices show promise in facilitating rapid stroke diagnosis, with the potential for improving time to treatment and informing prehospital stroke triage.


Assuntos
Sistemas Automatizados de Assistência Junto ao Leito , Acidente Vascular Cerebral , Humanos , Imageamento por Ressonância Magnética , Acidente Vascular Cerebral/diagnóstico por imagem , Tecnologia , Ultrassonografia
12.
Sci Rep ; 11(1): 10297, 2021 05 13.
Artigo em Inglês | MEDLINE | ID: mdl-33986450

RESUMO

Existing paradigms for stroke diagnosis typically involve computed tomography (CT) imaging to classify ischemic versus hemorrhagic stroke variants, as treatment for these subtypes varies widely. Delays in diagnosis and transport of unstable patients may worsen neurological status. To address these issues, we describe the development of a rapid, portable, and accurate eddy current damping (ECD) stroke sensor. Copper wire was wound to create large (11.4 cm), medium (4.5 cm), and small (1.5 cm) solenoid coils with varying diameters, with each connected to an inductance-to-digital converter. Eight human participants were recruited between December 15, 2019 and March 15, 2020, including two hemorrhagic stroke, two ischemic stroke, one subarachnoid hemorrhage, and three control participants. Observers were blinded to lesion type and location. A head cap with 8 horizontal scanning paths was placed on the patient. The sensor was tangentially rotated across each row on the patient's head circumferentially. Consent, positioning, and scanning with the sensor took roughly 15 min from start to end for each participant and all scanning took place at the patient bedside. The ECD sensor accurately classified and imaged each of the varying stroke types in each patient. The sensor additionally detected ischemic and hemorrhagic lesions located deep inside the brain, and its range is selectively tunable during sensor design and fabrication.


Assuntos
Acidente Vascular Cerebral/classificação , Tomografia Computadorizada por Raios X/métodos , Adulto , Animais , Feminino , Cobaias , Humanos , Masculino , Pessoa de Meia-Idade , Acidente Vascular Cerebral/diagnóstico por imagem
13.
Ann Biomed Eng ; 49(9): 2094-2102, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33537925

RESUMO

Millions of patients worldwide are implanted with permanent pacemakers for the treatment of cardiac arrhythmias and conduction disorders. The increased use of these devices has established a growing clinical need to mitigate associated complications. Pacemaker leads, in particular, present the primary risks in most implants. While wireless power transfer holds great promise in eliminating implantable device leads, anatomical constraints limit efficient wireless transmission over the necessary operational range. We thereby developed a transmitter-centered control system for wireless power transfer with sufficient power for continuous cardiac pacing. Device safety was validated using a computational model of the system within an MRI-based anatomical model. The pacer was then fabricated to meet the acute constraints of the anterior cardiac vein (ACV) to enable intravascular deployment while maintaining power efficiency. Our computational model revealed the wireless system to operate at > 50 times below the tissue energy absorption safety criteria. We further demonstrated the capacity for ex vivo pacing of pig hearts at 60 beats per minute (BPM) and in vivo pacing at 120 BPM following pacer deployment in the ACV. This work thus established the capacity for wireless intravascular pacing with the potential to eliminate complications associated with current lead-based deep tissue implants.


Assuntos
Estimulação Cardíaca Artificial , Marca-Passo Artificial , Animais , Fontes de Energia Elétrica , Humanos , Masculino , Modelos Anatômicos , Suínos , Tecnologia sem Fio
14.
IEEE Trans Biomed Eng ; 67(12): 3307-3316, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32248088

RESUMO

The elimination of integrated batteries in biomedical implants holds great promise for improving health outcomes in patients with implantable devices. However, despite extensive research in wireless power transfer, achieving efficient power transfer and effective operational range have remained a hindering challenge within anatomical constraints. OBJECTIVE: We hereby demonstrate an intravascular wireless and batteryless microscale stimulator, designed for (1) low power dissipation via intermittent transmission and (2) reduced fixation mechanical burden via deployment to the anterior cardiac vein (ACV, ∼3.8 mm in diameter). METHODS: We introduced a unique coil design circumferentially confined to a 3 mm diameter hollow-cylinder that was driven by a novel transmitter-based control architecture with improved power efficiency. RESULTS: We examined wireless capacity using heterogenous bovine tissue, demonstrating >5 V stimulation threshold with up to 20 mm transmitter-receiver displacement and 20° of misalignment. Feasibility for human use was validated using Finite Element Method (FEM) simulation of the cardiac cycle, guided by pacer phantom-integrated Magnetic Resonance Images (MRI). CONCLUSION: This system design thus enabled sufficient wireless power transfer in the face of extensive stimulator miniaturization. SIGNIFICANCE: Our successful feasibility studies demonstrated the capacity for minimally invasive deployment and low-risk fixation.


Assuntos
Fontes de Energia Elétrica , Tecnologia sem Fio , Animais , Bovinos , Simulação por Computador , Desenho de Equipamento , Humanos , Miniaturização , Próteses e Implantes
15.
Transpl Int ; 33(7): 806-818, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32198960

RESUMO

Pancreatic islet transplantation into the liver is an effective treatment for type 1 diabetes but has some critical limitations. The subcutaneous site is a potential alternative transplant site, requiring minimally invasive procedures and allowing frequent graft monitoring; however, hypoxia is a major drawback. Our previous study without scaffolding demonstrated post-transplant graft aggregation in the subcutaneous site, which theoretically exacerbates lethal intra-graft hypoxia. In this study, we introduce a clinically applicable subcutaneous islet transplantation platform using a biodegradable Vicryl mesh scaffold to prevent aggregation in a diabetic rat model. Islets were sandwiched between layers of clinically proven Vicryl mesh within thrombin-fibrin gel. In vitro, the mesh prevented islet aggregation and intra-islet hypoxia, which significantly improved islet viability. In vivo rat syngeneic islet transplantations into a prevascularized subcutaneous pocket demonstrated that the mesh significantly enhanced engraftment, as measured by assays for graft survival and function. Histological examination at 6 weeks showed well-vascularized grafts sandwiched in a flat shape between the mesh layers. The biodegradable mesh was fully absorbed by three months, which alleviated chronic foreign body reaction and fibrosis, and supported long-term graft maintenance. This simple graft shape modification approach is an effective and clinically applicable strategy for improved subcutaneous islet transplantation.


Assuntos
Diabetes Mellitus Experimental , Transplante das Ilhotas Pancreáticas , Ilhotas Pancreáticas , Animais , Glicemia , Diabetes Mellitus Experimental/cirurgia , Sobrevivência de Enxerto , Poliglactina 910 , Ratos , Telas Cirúrgicas
16.
Transplantation ; 103(2): 299-306, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-29781952

RESUMO

Islet transplantation is a promising treatment for type-1 diabetes; however, donor shortage is a concern. Even when a pancreas is available, low islet yield limits the success of transplantation. Islet culture enables pooling of multiple low-yield isolations into an effective islet mass, but isolated islets rapidly deteriorate under conventional culture conditions. Oxygen (O2) depletion in the islet core, which leads to central necrosis and volume loss, is one of the major reasons for this deterioration. METHODS: To promote long-term culture of human islets in PIM-R medium (used for islet research), we adjusted temperature (12°C, 22°C, and 37°C) and O2 concentration (21% and 50%). We simulated the O2 distribution in islets based on islet O2 consumption rate and dissolved O2 in the medium. We determined the optimal conditions for O2 distribution and volume maintenance in a 2-week culture and assessed viability and insulin secretion compared to noncultured islets. In vivo islet engraftment was assessed by transplantation into diabetic nonobese diabetic-severe combined immunodeficiency mouse kidneys. We validated our results using CMRL 1066 medium (used for clinical islet transplantation). RESULTS: Simulation revealed that 12°C of 50% O2 PIM-R culture supplied O2 effectively into the islet core. This condition maintained islet volume at greater than 90% for 2 weeks. There were no significant differences in viability and function in vitro or diabetic reversal rate in vivo between 2-week cultured and noncultured islets. Similar results were obtained using CMRL 1066. CONCLUSIONS: By optimizing temperature and O2 concentration, we cultured human islets for 2 weeks with minimal loss of volume and function.


Assuntos
Técnicas de Cultura de Células/métodos , Ilhotas Pancreáticas/citologia , Oxigênio/farmacologia , Trifosfato de Adenosina/farmacologia , Animais , Meios de Cultura , Humanos , Ilhotas Pancreáticas/fisiologia , Camundongos , Temperatura
17.
Biofabrication ; 11(1): 015011, 2018 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-30524058

RESUMO

Cell transplantation is a promising treatment for complementing lost function by replacing new cells with a desired function, e.g. pancreatic islet transplantation for diabetics. To prevent cell obliteration, oxygen supply is critical after transplantation, especially until the graft is sufficiently re-vascularized. To supply oxygen during this period, we developed a chemical-/electrical-free implantable oxygen transporter that delivers oxygen to the hypoxic graft site from ambient air by diffusion potential. This device is simply structured using a biocompatible silicone-based body that holds islets, connected to a tube that opens outside the body. In computational simulations, the oxygen transporter increased the oxygen level to >120 mmHg within grafts; in contrast, a control device that did not transport oxygen showed <6.5 mmHg. In vitro experiments demonstrated similar results. To test the effectiveness of the oxygen transporter in vivo, we transplanted pancreatic islets, which are susceptible to hypoxia, subcutaneously into diabetic rats. Islets transplanted using the oxygen transporter showed improved graft viability and cellular function over the control device. These results indicate that our oxygen transporter, which is safe and easily fabricated, effectively supplies oxygen locally. Such a device would be suitable for multiple clinical applications, including cell transplantations that require changing a hypoxic microenvironment into an oxygen-rich site.


Assuntos
Diabetes Mellitus Experimental/metabolismo , Diabetes Mellitus Experimental/terapia , Transplante das Ilhotas Pancreáticas/instrumentação , Ilhotas Pancreáticas/metabolismo , Oxigênio/metabolismo , Animais , Humanos , Ilhotas Pancreáticas/química , Transplante das Ilhotas Pancreáticas/métodos , Masculino , Oxigênio/química , Ratos Endogâmicos Lew
18.
Theranostics ; 8(6): 1636-1647, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29556346

RESUMO

Introduction: Obesity is associated with an increased risk of nonalcoholic fatty liver disease (NAFLD). While Magnetic Resonance Imaging (MRI) is a non-invasive gold standard to detect fatty liver, we demonstrate a low-cost and portable electrical impedance tomography (EIT) approach with circumferential abdominal electrodes for liver conductivity measurements. Methods and Results: A finite element model (FEM) was established to simulate decremental liver conductivity in response to incremental liver lipid content. To validate the FEM simulation, we performed EIT imaging on an ex vivo porcine liver in a non-conductive tank with 32 circumferentially-embedded electrodes, demonstrating a high-resolution output given a priori information on location and geometry. To further examine EIT capacity in fatty liver detection, we performed EIT measurements in age- and gender-matched New Zealand White rabbits (3 on normal, 3 on high-fat diets). Liver conductivity values were significantly distinct following the high-fat diet (p = 0.003 vs. normal diet, n=3), accompanied by histopathological evidence of hepatic fat accumulation. We further assessed EIT imaging in human subjects with MRI quantification for fat volume fraction based on Dixon procedures, demonstrating average liver conductivity of 0.331 S/m for subjects with low Body-Mass Index (BMI < 25 kg/m²) and 0.286 S/m for high BMI (> 25 kg/m²). Conclusion: We provide both the theoretical and experimental framework for a multi-scale EIT strategy to detect liver lipid content. Our preliminary studies pave the way to enhance the spatial resolution of EIT as a marker for fatty liver disease and metabolic syndrome.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Algoritmos , Fígado/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Tomografia/métodos , Tecido Adiposo/patologia , Adulto , Animais , Simulação por Computador , Impedância Elétrica , Eletrodos , Humanos , Fígado/patologia , Masculino , Modelos Biológicos , Hepatopatia Gordurosa não Alcoólica/patologia , Coelhos , Suínos , Tomografia/instrumentação
19.
Artigo em Inglês | MEDLINE | ID: mdl-29093829

RESUMO

BACKGROUND: Subretinal cell transplantation is a challenging surgical maneuver. This paper describes the preliminary findings of a new tissue injector for subretinal implantation of an ultrathin non-absorbable substrate seeded with human embryonic stem cell-derived retinal pigment epithelium (hESC-RPE). METHODS: Ultrathin Parylene-C substrates measuring 3.5 mm × 6.0 mm seeded with hESC-RPE (implant referred to as CPCB-RPE1) were implanted into the subretinal space of 12 Yucatan minipigs. Animals were euthanized immediately after the procedure and underwent spectral domain optical coherence tomography (SD-OCT) and histological analysis to assess the subretinal placement of the implant. Evaluation of the hESC-RPE cells seeded on the substrate was carried out before and after implantation using standard cell counting techniques. RESULTS: The tissue injector delivered the CPCB-RPE1 implant through a 1.5 mm sclerotomy and a 1.0-1.5 mm retinectomy. SD-OCT scans and histological examination revealed that substrates were precisely placed in the subretinal space, and that the hESC-RPE cell monolayer continued to cover the surface of the substrate after the surgical procedure. CONCLUSION: This innovative tissue injector was able to efficiently deliver the implant in the subretinal space of Yucatan minipigs, preventing significant hESC-RPE cell loss, minimizing tissue trauma, surgical complications and postoperative inflammation.

20.
PLoS One ; 12(8): e0183780, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28832685

RESUMO

BACKGROUND: Type 1 diabetes is an autoimmune disease that destroys insulin-producing beta cells in the pancreas. Pancreatic islet transplantation could be an effective treatment option for type 1 diabetes once several issues are resolved, including donor shortage, prevention of islet necrosis and loss in pre- and post-transplantation, and optimization of immunosuppression. This study seeks to determine the cause of necrotic loss of isolated islets to improve transplant efficiency. METHODOLOGY: The oxygen tension inside isolated human islets of different sizes was simulated under varying oxygen environments using a computational in silico model. In vitro human islet viability was also assessed after culturing in different oxygen conditions. Correlation between simulation data and experimentally measured islet viability was examined. Using these in vitro viability data of human islets, the effect of islet diameter and oxygen tension of the culture environment on islet viability was also analyzed using a logistic regression model. PRINCIPAL FINDINGS: Computational simulation clearly revealed the oxygen gradient inside the islet structure. We found that oxygen tension in the islet core was greatly lower (hypoxic) than that on the islet surface due to the oxygen consumption by the cells. The hypoxic core was expanded in the larger islets or in lower oxygen cultures. These findings were consistent with results from in vitro islet viability assays that measured central necrosis in the islet core, indicating that hypoxia is one of the major causes of central necrosis. The logistic regression analysis revealed a negative effect of large islet and low oxygen culture on islet survival. CONCLUSIONS/SIGNIFICANCE: Hypoxic core conditions, induced by the oxygen gradient inside islets, contribute to the development of central necrosis of human isolated islets. Supplying sufficient oxygen during culture could be an effective and reasonable method to maintain isolated islets viable.


Assuntos
Sobrevivência Celular , Ilhotas Pancreáticas/metabolismo , Oxigênio/metabolismo , Humanos , Modelos Logísticos , Consumo de Oxigênio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...